System · 8 elements

Houses, galpões and fences. One system.

Group I pre-tensioned concrete (NBR 8953). The same WALL90 panel rises vertically in houses and lies horizontally in galpões; the WALL50 fence closes the boundaries. Factory to site.

Scroll to see the system

System in numbers

8
elements in the catalogue
3
applications of one panel
4,5 m
houses, vertical (up to)
5,5 m
galpão, panel span (up to)
±1–2 mm
factory tolerance

The kit logic

Not loose products.

The same WALL90 panel solves three applications: it rises vertically in houses and apartments (up to 4.5 m), lies horizontally between H-columns for galpões, and the WALL50 fence closes the boundaries. The FLOOR120 slab completes the floors. Group I pre-tensioned concrete (NBR 8953), factory-cut, to a ±1–2 mm tolerance.

Houses & apartments

Houses & apartments

4×

WALL90 walls, vertical — up to 4.5 m.

Galpões

Galpões

3×

WALL90 horizontal, between H-columns — spans up to 5.5 m.

Fence & boundary

Fence & boundary

2×

50 mm panels in slotted H-columns.

Galpões

To go higher: the panel laid horizontal.

In houses the WALL90 rises vertically. For galpões and high clear heights, the same panel lies horizontally: the H-columns stand upright, spaced up to 6 metres apart, and each WALL90 panel spans the gap between them — up to 5.5 m. Course over course, the structure rises tall and stable. No masonry, no on-site formwork.

H-column 240×180

H-column 240×180

Post with a 90 mm slot. Spacing up to 6 m.

WALL90 panel

WALL90 panel

Lies horizontal and spans between the columns — up to 5.5 m.

The same WALL90-600/300 panel from the houses, applied horizontally.

Flagship

WALL90-600

Hollow-core structural panel — the system's flagship.

Spec sheet

  • Dimension600 × 90 mm
  • ConcreteC35
  • Mass≈ 148 kg/m²
  • Pre-tensioned hollow-core panel
  • 7 voids Ø58 mm
  • 4 wires CP Ø4.0 mm
  • Tongue-and-groove join
  • Spans up to 5.5 m (galpão)
WALL90-600

Catalogue

The eight pieces.

Houses & apartments

WALL90-600

WALL90-600

Hollow-core structural panel — the system's flagship.

Dimension
600 × 90 mm
Concrete
C35
Mass
≈ 148 kg/m²

House and apartment walls; galpões, horizontal.

WALL90-300

WALL90-300

Complementary half-width module.

Dimension
300 × 90 mm
Concrete
C35
Mass
≈ 148 kg/m²

Wall module adjustment.

WALL90-L

WALL90-L

Corner junction profile.

Dimension
290 × 200 × 90 mm
Concrete
C35

Wall corners.

WALL90-T

WALL90-T

Cross junction profile.

Dimension
290 × 242 × 90 mm
Concrete
C35

Internal/external wall junctions.

Galpões

WALL90-600

WALL90-600

Hollow-core structural panel — the system's flagship.

Dimension
600 × 90 mm
Concrete
C35
Mass
≈ 148 kg/m²

House and apartment walls; galpões, horizontal.

WALL90-300

WALL90-300

Complementary half-width module.

Dimension
300 × 90 mm
Concrete
C35
Mass
≈ 148 kg/m²

Wall module adjustment.

H-column 240×180

H-column 240×180

Slotted post for the galpão system.

Dimension
240 × 180 mm · fenda 90 mm

Galpões — receives WALL90 panels horizontally.

Slab

FLOOR120

FLOOR120

Pre-tensioned hollow-core slab for floors.

Dimension
600 × 120 mm
Concrete
C50
Mass
≈ 208 kg/m²

Floors and mid-floors, spans up to 6.0 m.

Fence & boundary

WALL50 / Fence

WALL50 / Fence

Concrete boundary panel.

Dimension
50 mm · seção sólida

Industrial fences and boundary walls.

H-column 150×150

H-column 150×150

Slotted post for the fence.

Dimension
150 × 150 mm · fenda 50 mm

Fence-panel supports.

On site

From piece to building.

The same elements, raised by a small crew — walls, openings and slab of a real build.

Pre-tensioned hollow-core slab
Pre-tensioned hollow-core slab
Factory-cut window opening
Factory-cut window opening
Internal circulation in WALL90 panels
Internal circulation in WALL90 panels

Specifications

The eight pieces, in one table.

WALL90-600

Dimension
600 × 90 mm
Concrete
C35
Mass
≈ 148 kg/m²

7 voids Ø58 · 4 wires CP Ø4.0 · tongue-and-groove

WALL90-300

Dimension
300 × 90 mm
Concrete
C35
Mass
≈ 148 kg/m²

3 voids Ø58 · 2 wires CP Ø4.0 · half-width

WALL90-L

Dimension
290 × 200 × 90 mm
Concrete
C35
Mass

L junction · 90° corner

WALL90-T

Dimension
290 × 242 × 90 mm
Concrete
C35
Mass

T junction · cross

H-column 240×180

Dimension
240 × 180 mm · fenda 90 mm
Concrete
Mass

90 mm slot · up to 6 m between columns

FLOOR120

Dimension
600 × 120 mm
Concrete
C50
Mass
≈ 208 kg/m²

5 voids Ø80 · C50 · spans up to 6.0 m

WALL50 / Fence

Dimension
50 mm · seção sólida
Concrete
Mass

Solid section · no voids

H-column 150×150

Dimension
150 × 150 mm · fenda 50 mm
Concrete
Mass

50 mm slot · integrated post

Group I pre-tensioned concrete (NBR 8953) · 3 mm chamfered edges · factory tolerance ±1–2 mm.

Made to measure

From your plan to an exact quote.

You design; we engineer every wall of your plan into an exact inventory of AFDC panels — piece by piece, no guesswork.

AFDC panels
  1. 01

    You send the plan

    Your architectural plan — the starting point.

  2. 02

    We engineer the panels

    Each wall becomes an exact sequence of AFDC panels and profiles.

  3. 03

    You get the quote

    A piece-by-piece quote, ready for the build.

Talk to the factory

How much is your project losing without seeing it?

Request a quote or schedule a visit to the factory in Pecém, 60 km from Fortaleza.

The factory · Pecém — São Gonçalo do Amarante, CE